Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Omega ; 9(3): 4027-4036, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38284067

RESUMO

Despite recent advances in nucleic acid delivery systems with the success of LNP vehicles, adeno-associated virus (AAV) remains the leading platform for targeted gene delivery due to its low immunogenicity to humans, high transduction efficiency, and range of serotypes with varying tropisms. Depending on the therapeutic goals and serotype used, different production conditions may be more amenable, generating an ever-growing need for rapid yet robust analytical techniques to support the high-quality manufacturing of AAV. A critical bottleneck exists for assessing full capsids where rapid, high-throughput techniques capable of analyzing a range of serotypes are needed. Here, we present a rapid, high-throughput analytical technique, microfluidic electrophoresis, for the assessment of full capsids compatible with AAV1, AAV2, AAV6, AAV8, and AAV9 without the need for assay modifications or optimizations, and AAV5 with some constraints. The method presented in this study uses a mathematical formulation we developed previously with a reference standard to combine the independently obtained capsid protein and single-stranded DNA (ssDNA) profiles to estimate the percentage of full capsids in a sample of unknown concentration. We assessed the ability to use a single serotype (AAV8) as the reference standard regardless of the serotype of the sample being analyzed so long as the melting temperature (Tm) of the capsids is within 12 °C from the Tm of AAV8. Using this method, we are able to characterize samples ±6.1% with an average analytical turnaround time of <5 min/sample, using only 10 µL/sample at a concentration of 2.5 × 1012 VG/mL.

2.
Analyst ; 149(5): 1509-1517, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38265070

RESUMO

The versatility, rapid development, and ease of production scalability of mRNA therapeutics have placed them at the forefront of biopharmaceutical research. However, despite their vast potential to treat diseases, their novelty comes with unsolved analytical challenges. A key challenge in ensuring sample purity has been monitoring residual, immunostimulatory dsRNA impurities generated during the in vitro transcription of mRNA. Here, we present a method that combines an enzyme, S1 nuclease, to identify and isolate dsRNA from an mRNA sample with a microfluidic electrophoresis analytical platform to characterize the impurity. After the method was developed and optimized, it was tested with clinically relevant, pseudouridine-modified 700 and 1800 bp dsRNA and 818-4451 nt mRNA samples. While the treatment impacted the magnitude of the fluorescent signal used to analyze the samples due to the interference of the buffer with the labeling of the sample, this signal loss was mitigated by 8.8× via treatment optimization. In addition, despite the mRNA concentration being up to 400× greater than that of the dsRNA, under every condition, there was a complete disappearance of the main mRNA peak. While the mRNA peak was digested, the dsRNA fragments remained physically unaffected by the treatment, with no change to their migration time. Using these samples, we detected 0.25% dsRNA impurities in mRNA samples using 15 µL with an analytical runtime of 1 min per sample after digestion and were able to predict their size within 8% of the expected length. The short runtime, sample consumption, and high throughput compatibility make it suitable to support the purity assessment of mRNA during purification and downstream.


Assuntos
Microfluídica , Vacinas de mRNA , RNA de Cadeia Dupla/genética , Eletroforese , RNA Mensageiro/genética
3.
Electrophoresis ; 43(20): 2044-2048, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35948488

RESUMO

A low-cost and straightforward hybrid NOA (Norland optical adhesive) 81-glass microchip electrophoresis device was designed and developed for protein separation using indirect fluorescence detection. This new microchip was first characterized in terms of surface charge density via electroosmotic mobility measurement and stability over time. A systematic determination of the electroosmotic mobility (µeo ) over a wide pH range (2-10) and at various ionic strengths (20-50 mM) was developed for the first time via the neutral marker approach in an original simple frontal methodology. The evolution of µeo was proved consistent with the silanol and thiol functions arising from the glass and the NOA materials, respectively. The repeatability and reproducibility of the measurements on different microchips (RSD < 14%) and within 15 days (less than 5% decrease) were successfully demonstrated. The microchip was then applied for the efficient electrophoretic separation of proteins in a zonal mode coupled with indirect fluorescence detection, which is, to our knowledge, the first proof of concept of capillary zone electrophoresis in this hybrid microsystem.


Assuntos
Eletroforese em Microchip , Eletroforese Capilar/métodos , Eletroforese em Microchip/métodos , Vidro/química , Proteínas/análise , Reprodutibilidade dos Testes , Compostos de Sulfidrila
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...